ABSORBER CONTROL ACTUATOR INSPECTION


  1. INSPECT ABSORBER CONTROL ACTUATOR


    1. A01DS2NE02
      Text in Illustration
      *a

      Component without harness connected

      (Absorber Control Actuator LH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LH
      Tester Connection Condition Specified Condition
      1 (FAL+) - 2 (FAL-) Always 6.4 to 7.2 Ω
      3 (FBL+) - 4 (FBL-) 6.4 to 7.2 Ω

      If the result is not as specified, replace the absorber control actuator.

    2. A01DS2NE01
      Text in Illustration
      *a

      Component without harness connected

      (Absorber Control Actuator RH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for RH
      Tester Connection Condition Specified Condition
      1 (FAR+) - 2 (FAR-) Always 6.4 to 7.2 Ω
      3 (FBR+) - 4 (FBR-) 6.4 to 7.2 Ω

      If the result is not as specified, replace the absorber control actuator.