HEIGHT CONTROL SENSOR INSPECTION


  1. INSPECT REAR HEIGHT CONTROL SENSOR


    1. Check the rear height control sensor.

      A01DQUTE02
      Text in Illustration
      *a

      Component without harness connected

      (Rear Height Control Sensor)

      *b Min. Low
      *c Normal *d Max. High
      A01DQPB 45° A01DMKT 45°

      1. Connect 3 dry cell batteries of 1.5 V in series.

      2. Connect the positive (+) end of the batteries to terminal 1 (SHB) of the height control sensor and the negative (-) end of the batteries to terminal 3 (SHG). While slowly moving the sensor link up and down, measure the voltage between terminal 2 (SHRR) and terminal 3 (SHG).

      3. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        for RHD
        Tester Connection Sensor Condition Specified Condition
        3 (SHG) - 2 (SHRR) High (45°) 4.4 to 4.6 V
        Normal (0°) 2.3 to 2.6 V
        Low (-45°) 0.4 to 0.6 V
        for LHD
        Tester Connection Sensor Condition Specified Condition
        3 (SHG) - 2 (SHRL) High (45°) 4.4 to 4.6 V
        Normal (0°) 2.3 to 2.6 V
        Low (-45°) 0.4 to 0.6 V

        Note

        Do not apply higher than 6 V.

        If the result is not as specified, replace the height control sensor.