GENERATOR INSPECTION


  1. INSPECT GENERATOR WITH CLUTCH PULLEY


    1. A01DNJV

      Hold the center of the generator with clutch pulley, and confirm that the outer ring turns counterclockwise and does not turn clockwise.

      Text in Illustration
      A01DQPB Free
      A01DMKT Lock

      If the result is not as specified, replace the generator with clutch pulley.

  2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


    1. A01DOH8E04
      Text in Illustration
      *1 Length

      Using a vernier caliper, measure the brush length.

      Standard length
      9.5 mm to 11.5 mm (0.374 to 0.453 in.)
      Minimum length
      4.5 mm (0.177 in.)

      If the length is less than the minimum, replace the brush holder assembly.

  3. INSPECT GENERATOR ROTOR ASSEMBLY


    1. A01DS7R

      Inspect that the bearing is not rough or worn.

      If necessary, replace the generator rotor assembly.

    2. A01DSLNE26
      Text in Illustration
      *1 Slip Ring

      Check the rotor for an open circuit.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Slip ring - Slip ring 20°C (68°F) 2.3 to 2.7 Ω

        If the result is not as specified, replace the generator rotor assembly.

    3. A01DRWHE21
      Text in Illustration
      *1 Slip Ring
      *2 Rotor Core

      Check if the rotor is grounded.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        Rotor - Slip ring Always 10 kΩ or higher

        If the result is not as specified, replace the generator rotor assembly.

    4. A01DUHR

      Using a vernier caliper, measure each slip ring diameter.

      Standard diameter
      14.2 to 14.4 mm (0.559 to 0.567 in.)
      Minimum diameter
      14.0 mm (0.551 in.)