INSPECT SHIFT SOLENOID VALVE SR
| *a | Component without harness connected (Shift Solenoid Valve SR) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the solenoid valve.
INSPECT SHIFT SOLENOID VALVE SLU AND SLT
| *a | Component without harness connected (Shift Solenoid Valve) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the solenoid valve.
INSPECT SHIFT SOLENOID VALVE SL1 AND SL2
| *a | Component without harness connected (Shift Solenoid Valve) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the solenoid valve.
INSPECT SHIFT SOLENOID VALVE S1
| *a | Component without harness connected (Shift Solenoid Valve S1) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the solenoid valve.
INSPECT SHIFT SOLENOID VALVE S2
| *a | Component without harness connected (Shift Solenoid Valve S2) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the solenoid valve.