RELAY ON-VEHICLE INSPECTION


  1. INSPECT STARTER RELAY (ST)


    1. A01DRZUE64

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the starter relay.

  2. INSPECT GLOW RELAY


    1. A01DRZUE63

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the glow relay.