CANISTER INSPECTION


  1. INSPECT CANISTER


    1. Visually check the canister for cracks or damage.

      If cracks or damage is found, replace the canister.

    2. A01DUBCE02
      Text in Illustration
      *1 Port A
      *2 Port B
      *3 Port C

      Using SST, inspect the canister.

      SST
      09992-00242
      OK
      Measurement Condition Specified Condition
      Ports B and C closed, vacuum applied to port A [1.96 kPa (15 mmHg, 0.579 in.Hg)] No leak
      Port C closed, vacuum applied to port A [1.96 kPa (15 mmHg, 0.579 in.Hg)] Air flows from port B

      Port C closed, air blow into port A [4.71 kPa (0.05 kgf/cm2, 0.7 psi)]

      Air flows from port B

      Air blow into port A [4.71 kPa (0.05 kgf/cm2, 0.7 psi)]

      Air flows from both ports B and C

      If the result is not as specified, replace the canister.