INSPECT AIR SWITCHING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
When measuring the resistance make sure that the surface temperature of the air switching valve is 20°C.
If the result is not as specified, replace the air switching valve assembly.
Check the operation of the air switching valve.
| *1 | Port A |
| *2 | Port B |
|
Air |
Check that air does not flow from port A to port B.
Note
Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.
If the result is not as specified, replace the air switching valve assembly.
| *1 | Port A |
| *2 | Port B |
|
Air |
Apply battery voltage across terminals 1 and 2.
Note
Apply voltage for 2 minutes or less.
Check that air flows from port A to port B.
If the result is not as specified, replace the air switching valve assembly.