Click here

PURGE VALVE INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT PURGE VSV


    1. A01DTMWE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω
      1 - Body ground Always 10 MΩ or higher
      2 - Body ground Always 10 MΩ or higher
      Tip:

      When measuring the coil resistance make sure that the surface temperature of the purge VSV is 20°C.

    2. Check the operation of the purge VSV.


      1. A01DNX5E03

        Check that air does not flow from port E to port F.

        Table 1. Text in Illustration
        *1 Port E
        *2 Port F
        *a Does not flow
        A01DQPB Air pressure
      2. A01DPRQE05

        Apply battery voltage to the connector and check the VSV operation.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → terminal 1

        Battery negative (-) → terminal 2

        Air flows from port E to port F
        Table 2. Text in Illustration
        *1 Port E
        *2 Port F
        A01DQPB Air pressure

        If the result is not as specified, replace the purge VSV.