INSTALL HEATED OXYGEN SENSOR
| *1 | Fulcrum Length |
Using SST, install the heated oxygen sensor.
Tech Tips
Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification Click here.
Make sure SST and the wrench are connected in a straight line.
Attach the wire harness clamp.
Connect the oxygen sensor connector.