DESCRIPTION
The blind spot monitor sensor RH receives a reverse signal from the back-up light switch assembly.
INSPECTION PROCEDURE
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
INSPECT BACK-UP LIGHT SWITCH ASSEMBLY
Remove the back-up light switch assembly (Click here).
Inspect the back-up light switch assembly (Click here).
CHECK HARNESS AND CONNECTOR (BACK-UP LIGHT SWITCH ASSEMBLY - BATTERY)
Disconnect the back-up light switch assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to Back-up Light Switch Assembly) |
CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BACK-UP LIGHT SWITCH ASSEMBLY)
Disconnect the R43 blind spot monitor sensor RH connector.
Disconnect the C41 back-up light switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here
REPLACE BACK-UP LIGHT SWITCH ASSEMBLYClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR