DATA LIST
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Cooler thermistor (room temperature sensor) / Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Thermistor assembly (ambient temperature sensor) / Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor (evaporator temperature sensor) / Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Driver side automatic light control sensor (solar sensor) / Min.: 0 Max.: 255 |
Driver side automatic light control sensor (solar sensor) value increases as brightness increases | - |
| Solar Sensor (P Side) | Front passenger side automatic light control sensor (solar sensor) / Min.: 0 Max.: 255 |
Front passenger side automatic light control sensor (solar sensor) value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor / Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature is displayed | - |
| Set Temperature (D Side) | Driver side set temperature / Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature / Min.: MAX COLD Max.: MAX HOT |
Front passenger side set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioning pressure sensor / Min.: -66.22 psi (gauge) Max.: 477.68 psi (gauge) |
Actual pressure is displayed | - |
| Regulator Control Current | Solenoid valve control current / Min.: 0 A Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| Air Mix Servo Targ Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) target pulse / Min.: 0 Max.: 255 |
MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) |
- |
| Air Mix Servo Actual Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (air mix*1) actual pulse / Min.: 0 Max.: 255 |
MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) |
- |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) target pulse / Min.: 0 Max.: 255 |
MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) |
- |
| Air Mix Servo Actual Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (air mix*2) actual pulse / Min.: 0 Max.: 255 |
MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) |
- |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse / Min.: 0 Max.: 255 |
FACE: 8 (pulse) B/L: 30 (pulse) FOOT (Manual mode): 67 (pulse) FOOT (Automatic mode): 60, 67, 74 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) |
- |
| Air Outlet Servo Actu Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse / Min.: 0 Max.: 255 |
FACE: 8 (pulse) B/L: 30 (pulse) FOOT (Manual mode): 67 (pulse) FOOT (Automatic mode): 60, 67, 74 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) |
- |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) target pulse / Min.: 0 Max.: 255 |
RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) |
- |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly (air inlet) actual pulse / Min.: 0 Max.: 255 |
RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) |
- |
| Shift Set Temperature | Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr |
Customized value displayed | - |
| Air Inlet Mode | Air inlet mode / Auto or Manual |
Customized value displayed | - |
| Compressor Mode | Compressor mode / Auto or Manual |
Customized value displayed | - |
| Evaporator Control | Evaporator control / Auto or Manual |
Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check / ON or OFF |
Customized value displayed | - |
| Fan speed increment control | Fan speed increment control / Slow, Normal, Fast |
Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/DEF auto mode / ON or OFF |
Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF auto blower speed increase / ON or OFF |
Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr |
Customized value displayed | - |
| Pls Servo Test Sts | Pulse servo motor test status / Wait, Move, Comp, Error, Stop |
Pulse servo motor test status | - |
| Flow Sensor | Flow sensor / Min.: 0.0 V Max.: 5.0 V |
A/C on, Blower switch HI: 0.7 to 3.8 V A/C off, Blower switch off: 3.8 to 4.2 V |
Flow sensor is malfunctioning when a constant value between 0.7 and 4.2 V is displayed continuously for more than 4 seconds. |
| A/C Cutoff Signal | A/C control cutoff signal / OFF or ON |
A/C switch on: OFF A/C switch off: ON |
- |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function / ON or OFF |
Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
*1: for Driver side
*2: for Front passenger side
ACTIVE TEST
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
| Magnetic Clutch Relay | A/C system operation | OFF, ON | - |
| Defogger Relay (Rear) | Defogger relay (engine room junction block assembly) | OFF, ON | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix*1) pulse | Min.: 0, Max.: 255 | Operates between 5 and 103 pulses |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (air mix*2) pulse | Min.: 0, Max.: 255 | Operates between 7 and 105 pulses |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse | Min.: 0, Max.: 255 | Operates between 8 and 97 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) target pulse | Min.: 0, Max.: 255 | Operates between 7 and 28 pulses |
*1: for Driver side
*2: for Front passenger side