FRONT SEAT CUSHION HEATER INSPECTION


  1. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY LH (for TMMK Made)


    1. A01HMYAE01
      Text in Illustration
      *a

      Component without harness connected

      (Front Seat Cushion Heater Assembly LH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-1 - B-3 Always Below 1 Ω
      A-2 - A-5 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - B-1 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - C-1 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - C-1 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - C-2 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - A-3 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-3 - C-1 Always Below 1 Ω
      A-3 - B-1 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω
      A-3 - A-5 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω
      A-3 - C-2 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω
      A-4 - B-2 Always Below 1 Ω
      A-5 - B-1 Always Below 1 Ω
      A-5 - C-2 Always Below 1 Ω
      A-5 - C-1 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω

      If the result is not as specified, replace the front seat cushion heater assembly LH.

  2. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY RH (for TMMK Made)


    1. A01HMYAE01
      Text in Illustration
      *a

      Component without harness connected

      (Front Seat Cushion Heater Assembly RH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-1 - B-3 Always Below 1 Ω
      A-2 - A-5 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - B-1 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - C-1 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - C-1 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - C-2 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-2 - A-3 20°C (68°F) to 25°C (77°F) 9 to 13.8 kΩ
      A-3 - C-1 Always Below 1 Ω
      A-3 - B-1 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω
      A-3 - A-5 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω
      A-3 - C-2 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω
      A-4 - B-2 Always Below 1 Ω
      A-5 - B-1 Always Below 1 Ω
      A-5 - C-2 Always Below 1 Ω
      A-5 - C-1 20°C (68°F) to 25°C (77°F) 3.2 to 4.1 Ω

      If the result is not as specified, replace the front seat cushion heater assembly RH.

  3. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY LH (for SIA Made)


    1. A01HOZLE03
      Text in Illustration
      *a

      Component without harness connected

      (Front Seat Cushion Heater Assembly LH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-1 - B-1 Always Below 1 Ω
      A-4 - B-2 Always Below 1 Ω
      A-1 - A-4 Always 3.21 to 3.85 Ω
      B-1 - B-2 Always 3.39 to 4.07 Ω
      A-2 - A-3 15°C (59°F) to 30°C (86°F) 4.9 to 8.2 kΩ

      If the result is not as specified, replace the front seat cushion heater assembly LH.

  4. INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY RH (for SIA Made)


    1. A01HOZLE03
      Text in Illustration
      *a

      Component without harness connected

      (Front Seat Cushion Heater Assembly RH)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-1 - B-1 Always Below 1 Ω
      A-4 - B-2 Always Below 1 Ω
      A-1 - A-4 Always 3.21 to 3.85 Ω
      B-1 - B-2 Always 3.39 to 4.07 Ω
      A-2 - A-3 15°C (59°F) to 30°C (86°F) 4.9 to 8.2 kΩ

      If the result is not as specified, replace the front seat cushion heater assembly RH.