CUSTOMIZE REMOTE ENGINE STARTER SYSTEM
Tech Tips
The following items can be customized.
Note
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
Customizing with the Techstream
Connect the Techstream to the DLC3.
Turn the engine switch on (IG).
Turn the Techstream on.
Enter the following menus: Customize Setting / Air Conditioner.
Select the setting by referring to the table below.
| Display | Default | Content | Setting | Relevant ECU |
|---|---|---|---|---|
| Air Conditioner Mode | User | This function controls the air conditioner when the remote engine start function is operating. | User/Auto | Remote Engine Starter ECU |
| Defogger Control | OFF | This function controls the window defogger operation when the remote engine start function is operating. | OFF/ON |