| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 7.7 mm (0.3031 in.) or more at 95°C (203°F) |
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | Battery voltage applied at 20°C (68°F) | 7.3 to 9.3 A |
| No. 2 cooling fan motor | Battery voltage applied at 20°C (68°F) | 7.3 to 9.3 A |
| Item | Tester Connection | Specified Condition |
|---|---|---|
| Fan relay | 3 - 5 | 10 kΩor higher (Battery voltage is not applied between terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (Battery voltage is applied between terminals 1 and 2) |
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator cap | Standard value (for brand-new cap) |
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| Minimum standard value (for used cap) |
78.5 kPa (0.8 kgf/cm2, 11.4 psi) |