HAZARD WARNING SWITCH INSPECTION


  1. INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (w/o Navigation System)


    1. A01635KE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      12 (F) - 8 (E) Hazard warning switch OFF 10 kΩ or higher
      12 (F) - 8 (E) Hazard warning switch ON Below 1 Ω

      If the result is not as specified, replace the integration control and panel assembly.

  2. INSPECT CLOCK ASSEMBLY (w/ Navigation System)


    1. A016392E02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      12 (F) - 2 (E) Hazard warning switch OFF 10 kΩ or higher
      12 (F) - 2 (E) Hazard warning switch ON Below 1 Ω

      If the result is not as specified, replace the clock assembly.