SLIDING ROOF SWITCH ASSEMBLY INSPECTION


  1. INSPECT SLIDING ROOF SWITCH ASSEMBLY (MAP LIGHT ASSEMBLY)


    1. Remove the sliding roof switch assembly (map light assembly).

      A01635LE02
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      R5-8 (DOWN) - R5-39 (GND) 1 Below 100 Ω
      R5-9 (UP) - R5-39 (GND) 1 1 kΩ or higher
      R5-10 (CLS) - R5-39 (GND) 1 1 kΩ or higher
      R5-11 (OPN) - R5-39 (GND) 1 1 kΩ or higher
      R5-8 (DOWN) - R5-39 (GND) 2 Below 100 Ω
      R5-9 (UP) - R5-39 (GND) 2 Below 100 Ω
      R5-10 (CLS) - R5-39 (GND) 2 1 kΩ or higher
      R5-11 (OPN) - R5-39 (GND) 2 1 kΩ or higher
      R5-8 (DOWN) - R5-39 (GND) 3 1 kΩ or higher
      R5-9 (UP) - R5-39 (GND) 3 Below 100 Ω
      R5-10 (CLS) - R5-39 (GND) 3 1 kΩ or higher
      R5-11 (OPN) - R5-39 (GND) 3 1 kΩ or higher
      R5-8 (DOWN) - R5-39 (GND) 4 1 kΩ or higher
      R5-9 (UP) - R5-39 (GND) 4 Below 100 Ω
      R5-10 (CLS) - R5-39 (GND) 4 1 kΩ or higher
      R5-11 (OPN) - R5-39 (GND) 4 Below 100 Ω
      R5-8 (DOWN) - R5-39 (GND) 5 1 kΩ or higher
      R5-9 (UP) - R5-39 (GND) 5 1 kΩ or higher
      R5-10 (CLS) - R5-39 (GND) 5 1 kΩ or higher
      R5-11 (OPN) - R5-39 (GND) 5 Below 100 Ω
      R5-8 (DOWN) - R5-39 (GND) 6 1 kΩ or higher
      R5-9 (UP) - R5-39 (GND) 6 1 kΩ or higher
      R5-10 (CLS) - R5-39 (GND) 6 Below 100 Ω
      R5-11 (OPN) - R5-39 (GND) 6 Below 100 Ω
      R5-8 (DOWN) - R5-39 (GND) 7 1 kΩ or higher
      R5-9 (UP) - R5-39 (GND) 7 Below 100 Ω
      R5-10 (CLS) - R5-39 (GND) 7 Below 100 Ω
      R5-11 (OPN) - R5-39 (GND) 7 Below 100 Ω
      R5-8 (DOWN) - R5-39 (GND) 8 1 kΩ or higher
      R5-9 (UP) - R5-39 (GND) 8 Below 100 Ω
      R5-10 (CLS) - R5-39 (GND) 8 Below 100 Ω
      R5-11 (OPN) - R5-39 (GND) 8 1 kΩ or higher
      R5-8 (DOWN) - R5-39 (GND) 9 Below 100 Ω
      R5-9 (UP) - R5-39 (GND) 9 Below 100 Ω
      R5-10 (CLS) - R5-39 (GND) 9 Below 100 Ω
      R5-11 (OPN) - R5-39 (GND) 9 1 kΩ or higher
      R5-8 (DOWN) - R5-39 (GND) 10 Below 100 Ω
      R5-9 (UP) - R5-39 (GND) 10 1 kΩ or higher
      R5-10 (CLS) - R5-39 (GND) 10 Below 100 Ω
      R5-11 (OPN) - R5-39 (GND) 10 1 kΩ or higher
      R5-7 (CHK) - R5-39 (GND) 11 Below 100 Ω

      If the result is not as specified, replace the sliding roof switch assembly (map light assembly).