WINDSHIELD DEICER SYSTEM Windshield Deicer does not Operate

DESCRIPTION

Pressing the windshield deicer switch with the engine switch on (IG) causes the indicator to come on and the system to be activated. After approximately 15 minutes, the system automatically stops and the indicator goes off.

WIRING DIAGRAM

A01638IE02

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK DEICER RELAY OPERATES


    1. Push the windshield deicer switch.

    2. Check that operation sound of the deicer relay is heard.

      OK
      Relay operating sound is heard.

    NG
    OK
  2. INSPECT DEICER RELAY


    1. A0162N8E01

      Remove the deicer relay.

    2. Measure the resistance of the windshield deicer relay.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 When battery voltage is not applied between terminals 10 kΩ or higher
      3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (DEICER RELAY - BATTERY)


    1. A0162KHE01

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      Engine room relay block No. 2 deicer relay 5 terminal - Body ground Always 11 to 14 V

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (DEICER RELAY - WINDSHIELD DEICER WIRE)


    1. Disconnect the windshield deicer wire

      A015YPDE01
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Engine room relay block No. 2 deicer relay 3 terminal - A44-1 (B2) Always Below 1 Ω
      Engine room relay block No. 2 deicer relay 3 terminal - A44-2 (B) Always Below 1 Ω

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (WINDSHIELD DEICER WIRE - BODY GROUND)


    1. A015Z0YE02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A44-3 (E) - Body ground Always Below 1 Ω

    NG
    OK
  6. INSPECT DEICER RELAY


    1. A0162N8E01

      Remove the deicer relay.

    2. Measure the resistance of the windshield deicer relay.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 When battery voltage is not applied between terminals 10 kΩ or higher
      3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω

    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (DEICER RELAY - BATTERY)


    1. A0162KHE01

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      Engine room relay block No. 2 deicer relay 1 terminal - Body ground Engine switch on (IG) 11 to 14 V

    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (DEICER RELAY - WINDSHIELD DEICER SWITCH)


    1. Disconnect the windshield deicer switch.

      A015ZR8E01
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Engine room relay block No. 2 deicer relay 2 terminal - J90-4 (D) Always Below 1 Ω
      Engine room relay block No. 2 deicer relay 2 terminal - Body ground Always 10 kΩ or higher

    NG
    OK
  9. CHECK HARNESS AND CONNECTOR (WINDSHIELD DEICER SWITCH - BATTERY)


    1. A015YI8E01

      Disconnect the windshield deicer switch.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      J90-5 (IG) - Body ground Engine switch on (IG) 11 to 14 V

    NG
    OK
  10. CHECK HARNESS AND CONNECTOR (WINDSHIELD DEICER SWITCH - BODY GROUND)


    1. A015YI8E02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      J90-3 (E) - Body ground Always Below 1 Ω

    NG
    OK