LIGHT CONTROL RHEOSTAT INSPECTION


  1. INSPECT LIGHT CONTROL RHEOSTAT


    1. A0161O2E03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (E) - 4 (RV) Turn the light control rheostat knob fully counterclockwise (MIN.) Approximately 0 Ω
      1 (E) - 4 (RV) Light control rheostat position is between MIN. and MAX. The value changes gradually (Between below 0Ω to 8 kΩ)
      1 (E) - 4 (RV) Turn the light control rheostat knob fully clockwise (MAX.) 8 kΩ or higher
      2 (TC) - 3 (T) Light control rheostat knob position is except below Below 1 Ω
      2 (TC) - 3 (T) Turn the light control rheostat knob fully clockwise (Tail cancel switch is ON) 10 kΩ or higher

      Tech Tips

      If the value is not as specified, replace the light control rheostat Click here.