SATELLITE SWITCH INSPECTION


  1. INSPECT SATELLITE SWITCH


    1. A0160U0E04

      Disconnect the J16 connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      2 (LSEL) - 5 (E) Satellite switch LH is pressed Below 1 Ω
      2 (LSEL) - 5 (E) Satellite switch LH is not pressed 10 kΩ or higher
      3 (SET) - 5 (E) Satellite switch ON/OFF is pressed Below 1 Ω
      3 (SET) - 5 (E) Satellite switch ON/OFF is not pressed 10 kΩ or higher
      4 (RSEL) - 5 (E) Satellite switch RH is pressed Below 1 Ω
      4 (RSEL) - 5 (E) Satellite switch RH is not pressed 10 kΩ or higher

      Tech Tips

      If the value is not as specified, replace the satellite switch Click here.