METER / GAUGE SYSTEM FAIL-SAFE CHART

Fuel Signal (Fuel Injection Signal)
Condition Response Recovery
While the engine switch is turned on (IG), fuel injection signal is interrupted for 60 seconds. Fuel gauge calibration is performed using average fuel consumption data. Normal data is received.
Engine Coolant Temperature Receiver Gauge
Condition Response Recovery
Engine coolant temperature data is interrupted for 5 seconds. The gauge needle indicates below C. Engine coolant temperature data is received.
Shift Indicator
Condition Response Recovery
"P" to "D" data is interrupted for 3 seconds. All indicator lights go off. Normal data is received.
A/T range data is interrupted for 3 seconds, or more than 2 items are received simultaneously. All indicator lights go off. Normal data is received.
ABS, EBD, BA, TRC, and VSC
Condition Response Recovery
ABS, EBD, BA, TRC, and VSC data is interrupted for 1 second. The warning light comes on. Normal data is received.
Door
Condition Response Recovery
Regular data is interrupted for 10 seconds. The data received most recently remains indicated. Normal data is received.
Driver Side Seat Belt
Condition Response Recovery
Driver side seat belt inner belt assembly data is interrupted for 10 seconds. The data received most recently remains indicated. Normal data is received.
Power Steering
Condition Response Recovery
EPS data is interrupted for 1 second. The indicator light comes on. Normal data is received.
Tail
Condition Response Recovery
Regular data is interrupted for 10 seconds. The data received most recently remains indicated. Normal data is received.
Beam
Condition Response Recovery
Regular data is interrupted for 10 seconds. The indicator light goes off. Normal data is received.
Airbag
Condition Response Recovery
Airbag data is interrupted for 10 seconds or there is a malfunction in the combination meter (meter CPU). The warning light comes on. Normal data is received.
Meter Illumination
Condition Response Recovery
Illumination data is interrupted for 10 seconds or abnormal data is received. The display remains in daytime mode. Normal data is received.
Multi-information Display
Condition Response Recovery
Cruise information data is interrupted for 60 seconds. The display becomes blank (only measurement units are displayed). Normal data is received.