ENTRY LOCK AND UNLOCK SWITCH INSPECTION


  1. INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY LH


    1. A0161G6E02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection (Symbols) Condition Specified Condition
      1 (TRG-) - 3 (TRG+) Lock switch not pushed 10 kΩ or higher
      1 (TRG-) - 3 (TRG+) Lock switch pushed Below 1 Ω

      If the result is not specified, replace the front door outside handle assembly LH.

  2. INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY RH


    1. A01615HE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection (Symbols) Condition Specified Condition
      1 (TRG-) - 3 (TRG+) Lock switch not pushed 10 kΩ or higher
      1 (TRG-) - 3 (TRG+) Lock switch pushed Below 1 Ω

      If the result is not specified, replace the front door outside handle assembly RH.