FRONT DOOR LOCK INSPECTION


  1. INSPECT FRONT DOOR LOCK ASSEMBLY LH (w/o Double Locking System)


    1. Check the operation of the door lock motor.


      1. Apply battery voltage and check the operation of the door lock motor.

        A0161UIE08
        OK
        Measurement Condition Door Lock Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 1 (UDL)

        Lock

        Battery positive (+) → 1 (UDL)

        Battery negative (-) → 4 (L)

        Unlock

        If the result is not as specified, replace the front door lock assembly LH.

    2. Check the operation of the door unlock detection switch.


      1. Measure the resistance according to the value(s) in the table below.

        A0161UIE09
        Standard Resistance
        Tester Connection Door Lock Condition Specified Condition
        7 (E) - 8 (LSSR) Lock 10 kΩ or higher
        7 (E) - 8 (LSSR) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly LH.

  2. INSPECT FRONT DOOR LOCK ASSEMBLY LH (w/ Double Locking System)


    1. Check the operation of the door lock motor and double lock motor.


      1. Apply battery voltage and check the operation of the door lock motor and double lock motor.

        A0160WME12
        OK
        Measurement Condition Door Lock Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 3 (UL)

        Lock

        Battery positive (+) → 3 (UL)

        Battery negative (-) → 4 (L)

        Unlock

        Battery positive (+) → 2 (DL)

        Battery negative (-) → 1 (UDL)

        Set

        Battery positive (+) → 1 (UDL)

        Battery negative (-) → 2 (DL)

        Unset

        Tech Tips


        • Move the door lock motor to the lock position and set the double locking system. Check that the doors cannot be unlocked by operating the control cable.

        • Move the door lock motor to the lock position and unset the double locking system. Check that the doors can be unlocked by operating the control cable.

        If the result is not as specified, replace the front door lock assembly LH.

    2. Check the operation of the door unlock detection switch and double lock position switch.


      1. Measure the resistance according to the value(s) in the table below.

        A0160WME10
        Standard Resistance
        Tester Connection Door Lock Condition Specified Condition
        7 (E) - 8 (LSSR) Lock 10 kΩ or higher
        7 (E) - 8 (LSSR) Unlock Below 1 Ω
        5 (E) - 6 (DLSR) Unset 10 kΩ or higher
        5 (E) - 6 (DLSR) Set Below 1 Ω

        If the result is not as specified, replace the front door lock assembly LH.

    3. Check the operation of the door key lock and unlock switch. (for LHD)


      1. Measure the resistance according to the value(s) in the table below.

        A015Z6UE01
        Standard Resistance
        Tester Connection Door Lock Condition Specified Condition
        7 (E) - 9 (L) Lock Below 1 Ω
        7 (E) - 9 (L) off 10 kΩ or higher
        7 (E) - 10 (UL) Unlock Below 1 Ω
        7 (E) - 10 (UL) Lock 10 kΩ or higher

        If the result is not as specified, replace the front door lock assembly LH.

  3. INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/o Double Locking System)


    1. Check the operation of the door lock motor.


      1. Apply battery voltage and check the operation of the door lock motor.

        A015ZWRE08
        OK
        Measurement Condition Door Lock Condition

        Battery positive (+) → 4 (DL)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 4 (DL)

        Unlock

        If the result is not as specified, replace the front door lock assembly RH.

    2. Check the operation of the door unlock detection switch.


      1. Measure the resistance according to the value(s) in the table below.

        A015ZWRE09
        Standard Resistance
        Tester Connection Door Lock Condition Specified Condition
        7 (LSSR) - 8 (E) Lock 10 kΩ or higher
        7 (LSSR) - 8 (E) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly RH.

    3. Check the operation of the door key lock and unlock switch. (for RHD)


      1. Measure the resistance according to the value(s) in the table below.

        A0160G6E01
        Standard Resistance
        Tester Connection Door Lock Condition Specified Condition
        6 (L) - 8 (E) Lock Below 1 Ω
        6 (L) - 8 (E) OFF 10 kΩ or higher
        5 (UL) - 8 (E) Unlock Below 1 Ω
        5 (UL) - 8 (E) Lock 10 kΩ or higher

        If the result is not as specified, replace the front door lock assembly RH.

  4. INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/ Double Locking System)


    1. Check the operation of the door lock motor and double lock motor.


      1. Apply battery voltage and check the operation of the door lock motor and double lock motor.

        A01637VE10
        OK
        Measurement Condition Door Lock Condition

        Battery positive (+) → 2 (L)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 2 (L)

        Unlock

        Battery positive (+) → 4 (DL)

        Battery negative (-) → 3 (UNDL)

        Set

        Battery positive (+) → 3 (UNDL)

        Battery negative (-) → 4 (DL)

        Unset

        Tech Tips


        • Move the door lock motor to the lock position and set the double locking system. Check that the doors cannot be unlocked by operating the control cable.

        • Move the door lock motor to the lock position and unset the double locking system. Check that the doors can be unlocked by operating the control cable.

        If the result is not as specified, replace the front door lock assembly RH.

    2. Check the operation of the door unlock detection switch and double lock position switch.


      1. Measure the resistance according to the value(s) in the table below.

        A01637VE11
        Standard Resistance
        Tester Connection Door Lock Condition Specified Condition
        7 (LSSR) - 8 (E) Lock 10 kΩ or higher
        7 (LSSR) - 8 (E) Unlock Below 1 Ω
        9 (DLSR) - 10 (E) Unset 10 kΩ or higher
        9 (DLSR) - 10 (E) Set Below 1 Ω

        If the result is not as specified, replace the front door lock assembly RH.

    3. Check the operation of the door key lock and unlock switch. (for RHD)


      1. Measure the resistance according to the value(s) in the table below.

        A015YHLE02
        Standard Resistance
        Tester Connection Door Lock Condition Specified Condition
        6 (L) - 8 (E) Lock Below 1 Ω
        6 (L) - 8 (E) OFF 10 kΩ or higher
        5 (UL) - 8 (E) Unlock Below 1 Ω
        5 (UL) - 8 (E) Lock 10 kΩ or higher