DATA LIST
Tech Tips
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Turn the engine switch off.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / Tilt&Telescopic / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| T&T Autoaway Function | Auto away and return function/ OFF or ON |
OFF: Auto away and return function is restrained ON: Auto away and return function is allowed |
- |
| Tilt Position | Current tilt position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Telesco Position | Current telescopic position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Tilt Return Position | Memorized tilt return position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Telesco Return Position | Memorized telescopic return position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| T&T Mem1 | Tilt & telescopic memory position 1/ Not Mem or Mem |
Not Mem: Position is not memorized Mem: Position is memorized |
- |
| Tilt Memory Pos 1 | Tilt data of memory position 1/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Telesco Memory Pos 1 | Telescopic data of memory position 1/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| T&T Mem2 | Tilt & telescopic memory position 2/ Not Mem or Mem |
Not Mem: Position is not memorized Mem: Position is memorized |
- |
| Tilt Memory Pos 2 | Tilt data of memory position 2/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Telesco Memory Pos 2 | Telescopic data of memory position 2/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| T&T Mem3 | Tilt & telescopic memory position 3/ Not Mem or Mem |
Not Mem: Position is not memorized Mem: Position is memorized |
- |
| Tilt Memory Pos 3 | Tilt data of memory position 3/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Telesco Memory Pos 3 | Telescopic data of memory position 3/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Tilt Up Limit | Uppermost tilt position/ Not Mem or Mem |
Not Mem: Position is not memorized Mem: Position is memorized |
- |
| Tilt Up Limit Position | Uppermost tilt position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Tilt Down Limit Pos | Lowermost tilt position/ Not Mem or Mem |
Not Mem: Position is not memorized Mem: Position is memorized |
- |
| Tilt Down Limit Position | Lowermost tilt position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Telesco Short Limit Pos | Shortest telescopic position/ Not Mem or Mem |
Not Mem: Position is not memorized Mem: Position is memorized |
- |
| Telesco Short Limit Pos | Shortest telescopic position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Telesco Long Limit | Longest telescopic position/ Not Mem or Mem |
Not Mem: Position is not memorized Mem: Position is memorized |
- |
| Telesco Long Limit Pos | Longest telescopic position data/ Min.: 0 Max.: 65535 |
7000 to 9000 H (28672 to 36864 edge) |
- |
| Up Switch | Input state of tilt up by manual switch/ OFF or ON |
OFF: Tilt up is not activated by manual switch ON: Tilt up is activated by manual switch |
- |
| Tilt Up SW(MPX) | Communication state of tilt up input by manual switch/ OFF or ON |
OFF: Tilt up is not activated by manual switch ON: Tilt up is activated by manual switch |
- |
| Down Switch | Input state of tilt down by manual switch/ OFF or ON |
OFF: Tilt down is not activated by manual switch ON: Tilt down is activated by manual switch |
- |
| Tilt Down SW(MPX) | Communication state of tilt down input by manual switch/ OFF or ON |
OFF: Tilt down is not activated by manual switch ON: Tilt down is activated by manual switch |
- |
| Telesco Short Switch | Input state of telescopic short by manual switch/ OFF or ON |
OFF: Telescopic short is not activated by manual switch ON: Telescopic short is activated by manual switch |
- |
| Telesco Short SW(MPX) | Communication state of telescopic short input by manual switch/ OFF or ON |
OFF: Telescopic short is not activated by manual switch ON: Telescopic short is activated by manual switch |
- |
| Telesco Long Switch | Input state of telescopic long by manual switch/ OFF or ON |
OFF: Telescopic long is not activated by manual switch ON: Telescopic long is activated by manual switch |
- |
| Telesco Long SW(MPX) | Communication state of telescopic long input by manual switch/ OFF or ON |
OFF: Telescopic long is not activated by manual switch ON: Telescopic long is activated by manual switch |
- |
| T&T Manual SW Data | Voltage data of manual switch/ Min.: 0 V Max.: 5 V |
Neutral position: Below 0.2 V Tilt up: 1.67 to 2.13 V Tilt down: 0.54 to 0.74 V Telescopic contract: 1.08 to 1.40 V Telescopic extend: 2.22 to 2.77 V |
- |
| Power Source Voltage | Voltage data of power supply/ Min.: 0 V Max.: 20 V |
Actual power supply voltage 11 to 14 V |
- |
| Freeze Speed Info | Vehicle speed data/ 0 Km Max.: 255 Km |
Actual vehicle speed | - |
| IG Switch (MPX) | Communication state of engine switch/ OFF or ON |
OFF: Communication is interrupted ON: Communication is normal |
- |
| IG Switch | Input state of engine switch/ OFF or ON |
OFF: Input signal is interrupted ON: Input signal is normal |
- |
| Key Switch/MPX | Communication state of key switch confirmation signal/ OFF or ON |
OFF: Communication is interrupted ON: Communication is normal |
- |
| Key Code Confirm(MPX) | Communication state of key code confirmation signal/ OFF or ON |
OFF: Communication is interrupted ON: Communication is normal |
- |
| Receive from Meter | Communication state of combination meter signal/ OK or Interpt |
OK: Communication is normal Interpt: Communication is interrupted |
- |
| Receive from Body | Communication state of body ECU signal/ OK or Interpt |
OK: Communication is normal Interpt: Communication is interrupted |
- |
| Receive from Seat ECU | Communication state of seat ECU signal/ OK or Interpt |
OK: Communication is normal Interpt: Communication is interrupted |
- |
| Receive from Combi | Communication state of combination switch ECU signal/ OK or Interpt |
OK: Communication is normal Interpt: Communication is interrupted |
- |
| Power ECU Info | Communication state of power source control ECU signal/ OK or Interpt |
OK: Communication is normal Interpt: Communication is interrupted |
- |
| The Number of DTCs | Number of diagnosis code/ Min.: 0 Max.: 255 |
Actual number of diagnosis code | - |
Enter the following menus: Body Electrical / Combination Switch / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Tilt Up SW | Tilt UP switch/ ON or OFF |
ON: Tilt up is activated by manual switch OFF: Tilt up is not activated by manual switch |
- |
| Tilt Down SW | Tilt DOWN switch/ ON or OFF |
ON: Tilt down is activated by manual switch OFF: Tilt down is not activated by manual switch |
- |
| Telesc Long SW | Telesco LONG switch status/ ON or OFF |
ON: Telescopic long is activated by manual switch OFF: Telescopic long is not activated by manual switch |
- |
| Telesc Short SW | Telesco SHORT switch status/ ON or OFF |
ON: Telescopic short is activated by manual switch OFF: Telescopic short is not activated by manual switch |
- |
ACTIVE TEST
Tech Tips
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Turn the engine switch off.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / Tilt&Telescopic / Active Test.
According to the display on the intelligent tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Tilt | Tilt operation | DOWN | OFF or DOWN |
| UP | OFF or UP | ||
| Telesco | Telescopic operation | LONG | OFF or LONG |
| SHORT | OFF or SHORT |