RELAY ON-VEHICLE INSPECTION


  1. INSPECT STOP LIGHT CONTROL RELAY (BRK-LP)


    1. Remove the stop light control BRK-LP relay.

    2. A0162XNE11

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Battery voltage is not applied between terminals 1 and 2 Below 1 Ω
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 4 Battery voltage is applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the value is not as specified, replace the stop light control BRK-LP relay.

  2. INSPECT ABS MOTOR RELAY (ABS MOTOR1 (FAIL SAFE))


    1. Remove the ABS MOTOR1 (fail safe) relay.

    2. A01632CE07

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the value is not as specified, replace the ABS MOTOR1 (fail safe) relay.

  3. INSPECT ABS MOTOR RELAY (ABS MOTOR3)


    1. Remove the ABS MOTOR3 relay.

    2. A015Z0QE09

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the value is not as specified, replace the ABS MOTOR3 relay.

  4. INSPECT ABS SOLENOID RELAY (ABS SOL)


    1. Remove the the ABS SOL relay.

    2. A01632CE08

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω

      If the value is not as specified, replace the the ABS SOL relay.