RELAY ON-VEHICLE INSPECTION


  1. INSPECT STARTER RELAY


    1. A0161CIE26

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω

      If the resistance is not as specified, replace the relay.

  2. INSPECT STARTER CUT RELAY


    1. A0161CIE26

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When battery voltage is applied to terminals 1 and 2 Below 1 Ω

      If the resistance is not as specified, replace the relay.