INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT
Tech Tips
The water inlet sub-assembly with thermostat is stamped with the valve opening temperature.
Immerse the water inlet sub-assembly with thermostat in water and gradually heat the water.
Check the valve opening temperature.
| Standard valve opening temperature |
|---|
| 80 to 84°C (176 to 183°F) |
If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
Check the valve lift.
| Standard valve lift |
|---|
| 10.0 mm (0.394 in.) or more at 95°C (203°F) |
If the valve lift is not as specified, replace the water inlet sub-assembly with thermostat.
Check that the valve closes when the water inlet sub-assembly with thermostat is at a low temperature (below 77°C (171°F)).