INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
Check operation of the No. 1 vacuum switching valve assembly.
Check that air does not flow from port E to port F.
Apply battery voltage across terminals 1 and 2.
Check that air flows from port E to port F.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.