PURGE VALVE INSPECTION


  1. INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY


    1. A0162EKE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω
      1 - Body ground Always 10 kΩ or higher
      2 - Body ground Always 10 kΩ or higher

      If the result is not as specified, replace the No. 1 vacuum switching valve assembly.

    2. Check operation of the No. 1 vacuum switching valve assembly.


      1. A0162KLE04

        Check that air does not flow from port E to port F.

      2. A0160E3E04

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the No. 1 vacuum switching valve assembly.