MASS AIR FLOW METER INSTALLATION


  1. INSTALL MASS AIR FLOW METER


    1. A016334

      Install the mass air flow meter with the 2 screws.

      Torque:
      1.0 N*m  { 10 kgf*cm, 9 in.*lbf }

      Note

      Make sure that the O-ring is not pinched.

    2. Connect the mass air flow meter connector.

  2. INSTALL ENGINE ROOM SIDE COVER RH (for LHD)


    1. A0161AL

      Install the engine room side cover RH with the 3 clips.

  3. INSTALL ENGINE ROOM SIDE COVER RH (for RHD)


    1. A015YK3

      Install the engine room side cover RH with the 4 clips.

  4. INSTALL COOL AIR INTAKE DUCT SEAL


    1. A015ZFO

      Install the cool air intake duct seal with the 9 clips.

  5. INSTALL V-BANK COVER SUB-ASSEMBLY


    1. A0160IP

      Engage the 4 clips to install the V-bank cover sub-assembly.

      Note


      • Be sure to engage the clips securely.

      • Do not apply excessive force or hit the cover to engage the clips. This may cause the cover to break.