NAVIGATION SYSTEM, Diagnostic DTC:B15C3

DTC Code DTC Name
B15C3 Speaker Output Short

DESCRIPTION

This DTC is stored when a malfunction occurs in the speakers.

DTC No. DTC Detection Condition Trouble Area
B15C3 A short is detected in the speaker output circuit.
  • Harness or connector

  • Speaker

  • Stereo component amplifier assembly

WIRING DIAGRAM

A0161L1E03
A0161WTE02

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR


    1. Disconnect the P48 stereo component amplifier assembly connector.

    2. Disconnect the L5 and M12 front No. 2 speaker assembly connectors.

    3. Disconnect the L2 and M4 front No. 3 speaker assembly connectors.

    4. Disconnect the L1 and M13 front No. 1 speaker assembly connectors.

    5. Disconnect the K3 front stereo component speaker assembly connector.

    6. Disconnect the N2 and O2 rear speaker assembly connectors.

    7. Disconnect the N5 and O5 rear No. 2 speaker assembly connectors.

    8. Disconnect the Q26 and Q22 rear stereo component speaker assembly connectors.

    9. Disconnect the P21 stereo component speaker assembly connector.

    10. Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      P48-13 (FR+) - Body ground Always 10 kΩ or higher
      P48-28 (FR-) - Body ground Always 10 kΩ or higher
      P48-12 (FL+) - Body ground Always 10 kΩ or higher
      P48-27 (FL-) - Body ground Always 10 kΩ or higher
      P48-5 (WFR+) - Body ground Always 10 kΩ or higher
      P48-20 (WFR-) - Body ground Always 10 kΩ or higher
      P48-4 (WFL+) - Body ground Always 10 kΩ or higher
      P48-19 (WFL-) - Body ground Always 10 kΩ or higher
      P48-7 (CTR+) - Body ground Always 10 kΩ or higher
      P48-22 (CTR-) - Body ground Always 10 kΩ or higher
      P48-15 (RR+) - Body ground Always 10 kΩ or higher
      P48-30 (RR-) - Body ground Always 10 kΩ or higher
      P48-14 (RL+) - Body ground Always 10 kΩ or higher
      P48-29 (RL-) - Body ground Always 10 kΩ or higher
      P48-11 (SR+) - Body ground Always 10 kΩ or higher
      P48-26 (SR-) - Body ground Always 10 kΩ or higher
      P48-10 (SL+) - Body ground Always 10 kΩ or higher
      P48-25 (SL-) - Body ground Always 10 kΩ or higher
      P48-6 (WF1+) - Body ground Always 10 kΩ or higher
      P48-21 (WF1-) - Body ground Always 10 kΩ or higher
    11. Measure the resistance between each of the front No. 2 speaker assemblies and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L5-1 - Body ground Always 10 kΩ or higher
      L5-2 - Body ground Always 10 kΩ or higher
      M12-1 - Body ground Always 10 kΩ or higher
      M12-2 - Body ground Always 10 kΩ or higher
    12. Measure the resistance between each of the rear speaker assemblies and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      N2-1 - Body ground Always 10 kΩ or higher
      N2-2 - Body ground Always 10 kΩ or higher
      O2-1 - Body ground Always 10 kΩ or higher
      O2-2 - Body ground Always 10 kΩ or higher

    NG
    OK
  2. INSPECT FRONT NO. 1 SPEAKER ASSEMBLY


    1. Remove the front No. 1 speaker assembly.

    2. A016021E07
      Text in Illustration
      *a

      Component without harness connected

      (Front No. 1 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 4.8 to 7.2 Ω

    NG
    OK
  3. INSPECT FRONT NO. 2 SPEAKER ASSEMBLY


    1. Remove the front No. 2 speaker assembly.

    2. A0161JPE24
      Text in Illustration
      *a

      Component without harness connected

      (Front No. 2 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 10 kΩ or higher

    NG
    OK
  4. REPLACE FRONT NO. 2 SPEAKER ASSEMBLY


    1. Replace the front No. 2 speaker assembly Click here.

    2. Clear the DTCs Click here.

    3. Recheck for DTCs and check that no DTCs are output.

      OK
      No DTCs are output.

      Tech Tips


      • Connect all the connectors to the front No. 2 speaker assemblies that were disconnected.

      • When there is a possibility that either the right or left front speaker is defective, inspect by interchanging the right one with the left one.

      • Perform the above inspection on both LH and RH sides.


    NG
    OK
  5. INSPECT FRONT NO. 3 SPEAKER ASSEMBLY


    1. Remove the front No. 3 speaker assembly.

    2. A01610CE74
      Text in Illustration
      *A for RH
      *B for LH
      *a

      Component without harness connected

      (Front No. 3 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (TWR+) - 3 (TWR-) Always 4.8 to 6.4 Ω
      1 (TWR+) - 2 (+) Always Below 1 Ω
      3 (TWR-) - 4 (-) Always Below 1 Ω
      1 (TWL+) - 3 (TWL-) Always 4.8 to 6.4 Ω
      1 (TWL+) - 2 (+) Always Below 1 Ω
      3 (TWL-) - 4 (-) Always Below 1 Ω

    NG
    OK
  6. INSPECT FRONT STEREO COMPONENT SPEAKER ASSEMBLY


    1. Remove the front stereo component speaker assembly.

    2. A0162B1E27
      Text in Illustration
      *a

      Component without harness connected

      (Front Stereo Component Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 4.8 to 6.4 Ω

    NG
    OK
  7. INSPECT REAR SPEAKER ASSEMBLY


    1. Remove the rear speaker assembly.

    2. A016021E07
      Text in Illustration
      *a

      Component without harness connected

      (Rear Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 5.0 to 7.0 Ω

    NG
    OK
  8. INSPECT REAR NO. 2 SPEAKER ASSEMBLY


    1. Remove the rear No. 2 speaker assembly.

    2. A01610CE75
      Text in Illustration
      *a

      Component without harness connected

      (Rear No. 2 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (+) - 3 (-) Always 10 kΩ or higher
      1 (+) - 2 (+TW) Always Below 1 Ω
      3 (-) - 4 (-TW) Always Below 1 Ω

    NG
    OK
  9. REPLACE REAR NO. 2 SPEAKER ASSEMBLY


    1. Replace the rear No. 2 speaker assembly Click here.

    2. Clear the DTCs Click here.

    3. Recheck for DTCs and check that no DTCs are output.

      OK
      No DTCs are output.

      Tech Tips


      • Connect all the connectors to the rear No. 2 speaker assemblies that were disconnected.

      • When there is a possibility that either the right or left front speaker is defective, inspect by interchanging the right one with the left one.

      • Perform the above inspection on both LH and RH sides.


    NG
    OK
  10. INSPECT REAR STEREO COMPONENT SPEAKER ASSEMBLY


    1. Remove the rear stereo component speaker assembly.

    2. A0162B1E27
      Text in Illustration
      *a

      Component without harness connected

      (Rear Stereo Component Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 4.8 to 6.4 Ω

    NG
    OK
  11. INSPECT STEREO COMPONENT SPEAKER ASSEMBLY


    1. Remove the stereo component speaker assembly.

    2. A01610CE77
      Text in Illustration
      *a

      Component without harness connected

      (Stereo Component Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 (WF1+) - 4 (WF1-) Always 6.2 to 7.8 Ω

    NG
    OK