ЭЛЕКТРОМАГНИТНЫЙ КЛАПАН ПЕРЕКЛЮЧЕНИЯ ПЕРЕДАЧ УСТАНОВКА

Click here
Click here
  1. Click here

    УСТАНОВИТЕ КОРПУС КЛАПАНОВ ТРАНСМИССИИ В СБОРЕ


    1. A017E9G

      Install the spring and check ball body.

    2. Align the groove of the manual valve with the pin of the lever.

    3. A017D1GE05

      Install the 17 bolts.

      11 N*m 110 kgf*cm 8 ft.*lbf
      Note:
      • Push the valve body against the accumulator piston springs and check ball body to install the valve body.

      • First, temporarily tighten the bolts marked (1) in the illustration because they are positioning bolts.

      Bolt length
      Bolt A
      25 mm (0.98 in.)
      Bolt B
      57 mm (2.24 in.)
      Bolt C
      41 mm (1.61 in.)
  2. Click here

    УСТАНОВИТЕ СЕТЧАТЫЙ МАСЛЯНЫЙ ФИЛЬТР КОРПУСА КЛАПАНОВ В СБОРЕ


    1. A017FA6

      Coat a new O-ring with ATF.

    2. Install the O-ring to the oil strainer.

    3. A017EEM

      Install the oil strainer with the 3 bolts.

      11 N*m 110 kgf*cm 8 ft.*lbf
  3. Click here

    УСТАНОВИТЕ ЖГУТ ЭЛЕКТРОПРОВОДКИ ТРАНСМИССИИ


    1. A017CAKE08

      Coat a new O-ring with ATF.

    2. Install the ATF temperature sensor with the lock plate and bolt.

      6.6 N*m 67 kgf*cm 58 in.*lbf
    3. Connect the 7 shift solenoid valve connectors.

  4. Click here

    УСТАНОВИТЕ МАСЛЯНЫЙ ПОДДОН АВТОМАТИЧЕСКОЙ ТРАНСМИССИИ В СБОРЕ


    1. A017EJDE03

      Install the 2 magnets in the oil pan.

    2. Apply adhesive to the 18 bolts.

      Adhesive
      Toyota Genuine Adhesive 1344, Three Bond 1344 or equivalent
    3. A017DMJ

      Install the oil pan and a new gasket to the transaxle case with the 18 bolts.

      7.8 N*m 80 kgf*cm 69 in.*lbf
      Note:

      Apply adhesive to the bolts and tighten them within 10 minutes of application.

  5. Click here

    УСТАНОВИТЕ АВТОМАТИЧЕСКУЮ ТРАНСМИССИЮ В СБОРЕ

    (см. стр.Click here).

  6. Click here

    ПОДСОЕДИНИТЕ ПРОВОД К ОТРИЦАТЕЛЬНОМУ ВЫВОДУ АККУМУЛЯТОРНОЙ БАТАРЕИ

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).