SLIDING ROOF SYSTEM Sliding Roof does not Move by Operating Sliding Roof Control Switch

DESCRIPTION

The sliding roof system uses a LIN communication protocol on the multiplex communication system. Inspect the communication system by following HOW TO PROCEED WITH TROUBLESHOOTING Click here to ensure that there are no problems with the multiplex communication system before troubleshooting the sliding roof system. The sliding roof system prohibits the AUTO UP/DOWN function if the jam protection function malfunctions. Check that there are no DTCs output before troubleshooting the sliding roof system. If any sliding roof system DTCs are output, perform troubleshooting on the output DTCs first.

WIRING DIAGRAM

A017G47E01

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT FUSE (S/ROOF, ECU-IG NO. 1)


    1. Remove the S/ROOF and ECU-IG No. 1 fuses from the instrument panel junction block.

    2. Measure the resistance of the fuses.

      Standard resistance
      Below 1 Ω

    NG
    OK
  2. CHECK WIRE HARNESS (SLIDING ROOF CONTROL ECU - BATTERY AND BODY GROUND)


    1. A017B8QE14

      Disconnect the Q12 connector.

    2. Measure the voltage and resistance according to the value(s) in the table below.

      Standard voltage
      Tester Connection Condition Specified Condition
      Q12-1 (B) - Body ground Always 10 to 14 V
      Q12-5 (IG) - Body ground Ignition switch on (IG) 10 to 14 V
      Q12-5 (IG) - Body ground Ignition switch off Below 1 V
      Standard resistance
      Tester Connection Condition Specified Condition
      Q12-2 (E) - Body ground Always Below 1 Ω

    NG
    OK
  3. PERFORM ACTIVE TEST BY INTELLIGENT TESTER (SLIDING ROOF OPERATION)


    1. Select the ACTIVE TEST, use the intelligent tester to generate a control command, and then check that the sliding roof slides open/close and tilts up/down Click here.

      SLIDE ROOF:
      Tester Display Test Part Control Range Diagnostic Note

      Slide Roof

      (Slide Roof)

      Operate sliding roof SLIDE CLOSE/TILT UP

      CLOSE/UP: Sliding roof SLIDE CLOSE or TILT UP operation occurs.

      OFF: Sliding roof is not operating.

      -

      Slide Roof

      (Slide Roof)

      Operate sliding roof SLIDE OPEN/TILT DOWN

      OPN/DWN: Sliding roof SLIDE OPEN or TILT DOWN operation occurs.

      OFF: Sliding roof is not operating.

      -
      OK
      Sliding roof operates normally.

    NG
    OK
  4. READ VALUE USING INTELLIGENT TESTER (SLIDING ROOF CONTROL ECU)


    1. Use the DATA LIST to check if the sliding roof switch assembly is functioning properly Click here.

      SLIDE ROOF:
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note

      Hall IC1 Pulse

      (Hall IC1 Pulse)

      Sliding roof operation signal/LO or HI

      LO: Sliding roof motor is not operating.

      HI: Sliding roof motor is operating.

      -

      Hall IC1 Status

      (Hall IC1 Status)

      Sliding roof operation signal/NORMAL or LOCK

      NORMAL: Sliding roof motor is operating.

      LOCK: Sliding roof motor is not operating.

      -

      Hall IC2 Pulse

      (Hall IC2 Pulse)

      Sliding roof operation signal/LO or HI

      LO: Sliding roof motor is not operating.

      HI: Sliding roof motor is operating.

      -

      Hall IC2 Status

      (Hall IC2 Status)

      Sliding roof operation signal/NORMAL or LOCK

      NORMAL: Sliding roof motor is operating.

      LOCK: Sliding roof motor is not operating.

      -

    NG
    OK
  5. READ VALUE USING INTELLIGENT TESTER (SLIDING ROOF SWITCH ASSEMBLY)


    1. Use the DATA LIST to check if the sliding roof switch assembly is functioning properly Click here.

      SLIDE ROOF:
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note

      Open SW

      (Open Switch)

      Slide switch open signal/ON or OFF

      ON: OPEN switch is pressed.

      OFF: OPEN switch is not pressed.

      -

      Close SW

      (Close Switch)

      Slide switch close signal/ON or OFF

      ON: CLOSE switch is pressed.

      OFF: CLOSE switch is not pressed.

      -

      Up SW

      (Up Switch)

      Tilt switch up signal/ON or OFF

      ON: UP switch is pressed.

      OFF: UP switch is not pressed.

      -

      Down SW

      (Down Switch)

      Tilt switch down signal/ON or OFF

      ON: DOWN switch is pressed.

      OFF: DOWN switch is not pressed.

      -
      OK
      The intelligent tester displays as shown in the table according to the operation of each switch.

    NG
    OK
  6. INSPECT ROOF CONSOLE BOX ASSEMBLY (SLIDING ROOF SWITCH ASSEMBLY)


    1. A017ER5E02

      Remove the roof console box assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      Q1-3 (CLS) - Q1-2 (GND) CLOSE Below 100 Ω
      Q1-4 (OPN) - Q1-2 (GND) OPEN Below 100 Ω
      Q1-5 (DOWN) - Q1-2 (GND) DOWN Below 100 Ω
      Q1-6 (UP) - Q1-2 (GND) UP Below 100 Ω
      Q1-3 (CLS) - Q1-2 (GND) OPEN 1 kΩ or higher
      Q1-4 (OPN) - Q1-2 (GND) CLOSE 1 kΩ or higher
      Q1-5 (DOWN) - Q1-2 (GND) UP 1 kΩ or higher
      Q1-6 (UP) - Q1-2 (GND) DOWN 1 kΩ or higher

    NG
    OK
  7. CHECK WIRE HARNESS (SLIDING ROOF CONTROL ECU - ROOF CONSOLE BOX ASSEMBLY)


    1. A017BC9E02

      Remove the Q12 and Q1 connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      Q12-2 (E) - Q1-2 (GND) Always Below 1 Ω
      Q12-7 (OPN) - Q1-4 (OPN) Always Below 1 Ω
      Q12-8 (DWN) - Q1-5 (DOWN) Always Below 1 Ω
      Q12-9 (CLS) - Q1-3 (CLS) Always Below 1 Ω
      Q12-10 (UP) - Q1-6 (UP) Always Below 1 Ω
      Q1-3 (CLS) - Body ground Always 10 kΩ or higher
      Q1-4 (OPN) - Body ground Always 10 kΩ or higher
      Q1-2 (GND) - Body ground Always Below 1 Ω
      Q1-5 (DOWN) - Body ground Always 10 kΩ or higher
      Q1-6 (UP) - Body ground Always 10 kΩ or higher

    NG