| DTC Code | DTC Name |
|---|---|
| Power Source Circuit |
DESCRIPTION
This circuit is the power source for the clock assembly. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission.
If the clock assembly displays "1:00" when the ignition switch off, then on (IG) again, the B (*1) or +B (*2) terminal has a malfunction.
The maximum clock assembly margin of error is -4 to 4 seconds per day when the temperature is between -20°C (-4°F) and 60°C (140°F).
*1: w/o Multi-information Display
*2: w/ Multi-information Display
INSPECTION PROCEDURE
PROCEDURE
CHECK HARNESS AND CONNECTOR
Disconnect the E20 (*1) or E9 (*2) connector.
Measure the voltage according to the value(s) in the table below.
| Standard voltage | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
*1: w/o Multi-information Display
*2: w/ Multi-information Display
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
*1: w/o Multi-information Display
*2: w/ Multi-information Display
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
REPLACE CLOCK ASSEMBLY (w/ Multi-information Display)Click here
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE CLOCK ASSEMBLY (w/o Multi-information Display)Click here