METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is on (IG), the indicator will not operate.

WIRING DIAGRAM

A017B53E02

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT COMBINATION METER ASSEMBLY


    1. A017B5ME01

      Disconnect the E1 connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      E1-20 (ES) - Body ground Always Below 1 Ω
      E1-40 (E2) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Condition Specified Condition
      E1-1 (IG+) - Body ground Ignition switch on (IG) 10 to 14 V
      E1-21 (B) - Body ground Always 10 to 14 V
      E1-22 (B2) - Body ground Always 10 to 14 V

    NG
    OK