FRONT DOOR LOCK INSPECTION


  1. INSPECT FRONT DOOR LOCK ASSEMBLY (for Driver Side)


    1. Apply the battery voltage to the motor terminals and check the operation of the door lock motor.

      A017B20E01
      OK
      Measurement Condition Specified Condition

      Battery positive (+) → 4 (L)

      Battery negative (-) → 1 (UL)

      Locked

      Battery positive (+) → 1 (UL)

      Battery negative (-) → 4 (L)

      Unlocked
    2. Measure the resistance of the door lock position switch.

      Standard resistance
      Tester Connection Measurement Condition Door Lock Condition Specified Condition
      7 - 8

      Battery positive (+) → Terminal 4

      Battery negative (-) → Terminal 1

      Locked 10 kΩ or higher
      7 - 8

      Battery positive (+) → Terminal 1

      Battery negative (-) → Terminal 4

      Unlocked Below 1 Ω
    3. Measure the resistance of the door key lock and unlock switch operation.


      1. A017D9TE07

        for LHD models:

        Standard resistance
        Tester Connection Condition Specified Condition
        7 - 9 Locked Below 1 Ω

        7 - 9

        7 - 10

        OFF (Free) 10 kΩ or higher
        7 - 10 Unlocked Below 1 Ω

        If the result is not as specified, replace the door lock assembly.

      2. A017F7ME01

        for RHD models:

        Standard resistance
        Tester Connection Condition Specified Condition
        8 - 6 Locked Below 1 Ω

        8 - 6

        8 - 5

        OFF (Free) 10 kΩ or higher
        8 - 5 Unlocked Below 1 Ω

        If the result is not as specified, replace the door lock assembly.

  2. INSPECT FRONT DOOR LOCK ASSEMBLY (for Front Passenger Side)


    1. Apply the battery voltage to the motor terminals and check the operation of the door lock motor.

      A017B20E02
      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 4

      Battery negative (-) → Terminal 1

      Locked

      Battery positive (+) → Terminal 1

      Battery negative (-) → Terminal 4

      Unlocked

      If the result is not as specified, replace the door lock assembly.

    2. Measure the resistance of the door lock position switch.

      Standard resistance
      Tester Connection Measurement Condition Door Lock Condition Specified Condition
      7 - 8

      Battery positive (+) → Terminal 4

      Battery negative (-) → Terminal 1

      Locked 10 kΩ or higher
      7 - 8

      Battery positive (+) → Terminal 1

      Battery negative (-) → Terminal 4

      Unlocked Below 1Ω