Click here

VANITY LIGHT INSPECTION

Click here
Click here
  1. Click here

    INSPECT VANITY LIGHT ASSEMBLY


    1. A017FGOE08

      Measure the voltage according to the value(s) in the table below.

      Standard voltage
      LH Side
      Tester Connection Condition Specified Condition
      Q8-1 - Q8-2 Visor raise Below 1 V
      Visor lower and mirror cover open 11 to 14 V
      Visor lower and mirror cover close Below 1 V
      RH Side
      Tester Connection Condition Specified Condition
      Q6-1 - Q6-2 Visor raise Below 1 V
      Visor lower and mirror cover open 11 to 14 V
      Visor lower and mirror cover close Below 1 V

      If the result is not as specified, there is a malfunction on the wire harness side.

      If the result is as specified, but the vanity light does not come on, replace the bulb.