ROOM LIGHT ASSEMBLY (for Center) INSPECTION


  1. INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Standard)


    1. A017F0ZE03

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      Q2-2 - Body ground Always Below 1 Ω

      If the result is not as specified, repair or replace harness or connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Condition Specified Condition
      Q2-1 - Body ground Always 11 to 14 V

      If the result is not as specified, repair or replace the harness or connector.

  2. INSPECT NO. 1 ROOM LIGHT ASSEMBLY (for Independent Type)


    1. A017BEKE02

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      LH Side
      Tester Connection Condition Specified Condition
      Q4-3 - Body ground Always Below 1 Ω
      RH Side
      Tester Connection Condition Specified Condition
      Q3-3 - Body ground Always Below 1 Ω

      If the result is not as specified, repair or replace harness or connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      LH Side
      Tester Connection Condition Specified Condition
      Q4-2 - Body ground Always 11 to 14 V
      RH Side
      Tester Connection Condition Specified Condition
      Q3-2 - Body ground Always 11 to 14 V

      If the result is not as specified, repair or replace the harness or connector.