ENGINE IMMOBILISER SYSTEM (w/ Smart Entry and Start System) Security Indicator Light Circuit

DESCRIPTION

The security indicator light blinks continuously due to a continuous signal received from the certification ECU (smart key ECU assembly) while in the armed state.

WIRING DIAGRAM

A017C36E01

INSPECTION PROCEDURE

Note

If the certification ECU (smart key ECU assembly) is replaced, register the key and ECU communication ID.

PROCEDURE


  1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SECURITY INDICATOR LIGHT)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the tester on.

    4. Perform the Active Test according to the display on the tester.

      Smart Key (Certification ECU (Smart Key ECU Assembly)):
      Tester Display Test Part Control Range Diagnostic Note
      Security Indic Security indicator light ON/OFF -
      OK
      The security indicator light turns on and off according to the tester operation.

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU - SECURITY INDICATOR LIGHT)


    1. A017F0UE01

      Disconnect the certification ECU (smart key ECU assembly) and security indicator light connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      D36-2 (IND) - E13-2 (IND+) Always Below 1 Ω
      D36-2 (IND) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT - BODY GROUND)


    1. A017E49E06

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      E13-5 (E) - Body ground Always Below 1 Ω

    NG