| DTC Code | DTC Name |
|---|---|
| Security Indicator Light Circuit |
DESCRIPTION
Even when the theft deterrent system is in the disarmed state, the security indicator light blinks due to a signal output from the immobiliser system. The security indicator light blinks continuously due to a continuous signal received from the immobiliser system while in the armed state.
The main body ECU causes the security indicator light to come on or blink only during the arming preparation state and alarm sounding state.
INSPECTION PROCEDURE
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the intelligent tester main switch on.
Select the item below in the Active Test and then check that the indicator operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Security Indicator | Security indicator light | ON / OFF | - |
| OK |
|---|
| The security indicator light blinks or goes off correctly when operating it through the intelligent tester. |
CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT - MAIN BODY ECU)
Disconnect the D9 ECU connector.
Disconnect the E13 connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
INSPECT SECURITY INDICATOR LIGHT
Reconnect the E13 connector with the D9 ECU connector still disconnected.
Apply battery voltage from the wire harness back side between the specified terminals of the indicator, and check the lighting condition of the security indicator light.
| Standard | ||||
|---|---|---|---|---|
|
If the positive (+) lead and the negative (-) lead are incorrectly connected, the security indicator light will not come on.
Voltage of more than 12 V will damage the security indicator light.
If the voltage is too low, the security indicator light will not come on.
REPLACE MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK)
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLEClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE SECURITY INDICATOR LIGHTClick here