OCCUPANT DETECTION SENSOR (for Manual Seat) INSPECTION


  1. INSPECT OCCUPANT DETECTION SENSOR (SEPARATE TYPE FRONT SEAT CUSHION COVER)


    1. A017DXZE04

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 3 The passenger seat is occupied Below 100 Ω
      1 - 3 The passenger seat is not occupied 1 MΩ or higher

      If the result is not as specified, replace the occupant detection sensor.