DESCRIPTION
The display image signal from the multi-media module receiver assembly is sent to the accessory meter assembly using a digital communication cable.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
CHECK DIGITAL COMMUNICATION CABLE CONNECTOR
Check if the digital communication cable connectors between the multi-media module receiver assembly and the accessory meter assembly have any connection problems Click here.
Check that the screen display is normal.
| OK |
|---|
| Screen display is normal. |
| NG |
|
CHECK ACCESSORY METER ASSEMBLY Click here |
| OK |
|
USE SIMULATION METHOD TO CHECK Click here
CHECK ACCESSORY METER ASSEMBLY
Temporarily replace the accessory meter assembly Click here.
Check that the screen display is normal.
| OK |
|---|
| Screen display is normal. |
| NG |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| OK |
|
END (ACCESSORY METER ASSEMBLY IS DEFECTIVE)