INSPECT HEIGHT CONTROL COMPRESSOR (EXHAUST VALVE)
Measure the resistance of the exhaust valve.
Measure the resistance according to the value(s) in the table.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
Check the exhaust valve operation.
Connect terminal 1 to the battery positive (+) terminal, and terminal 2 to the battery negative (-) terminal.
Check the operating sound of the height control valve.
| OK |
|---|
| It should make an operating sound (click). |
INSPECT HEIGHT CONTROL COMPRESSOR (COMPRESSOR MOTOR)
Check the compressor operation.
Connect terminal 1 (B) to the battery positive (+) terminal, and terminal 2 (E) to the battery negative (-) terminal.
Check the operation of the compressor motor.
| OK |
|---|
| Motor operates. |
Note
Do not operate the height control compressor for 60 seconds or more.
Since a short and a lock-up inside the height control compressor cause excessive current to flow, stop operation immediately when the compressor motor does not operate.