CONTROL VALVE ASSEMBLY (for Front Side) INSPECTION


  1. INSPECT NO. 1 HEIGHT CONTROL VALVE SUB-ASSEMBLY


    1. A01GIVNE01

      Measure the resistance according to the value(s) in the table.

      Standard resistance:
      Tester Connection Condition Specified Condition
      1 (RH+) - 2 (E) at 20°C (68°F) 10 to 14 Ω
      3 (LH+) - 2 (E) 10 to 14 Ω
    2. A01GIVNE01

      Check the operating sound of the height control valve when battery voltage is applied to the terminals.

      Battery Positive Battery Negative
      1 (RH+) 2 (E)
      3 (LH+) 2 (E)
      OK
      It makes an operating sound.