AUTOMATIC TRANSMISSION SYSTEM, Diagnostic DTC:P2769, P2770

DTC Code DTC Name
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

DESCRIPTION

Based on the on/off condition of solenoid valve SL, the TCM controls the fluid pressure to the lock-up relay valve, and performs lock-up control.

DTC Code DTC Detection Condition Trouble Area
P2769

TCM detects a short in the solenoid valve SL circuit 2 times when solenoid valve SL is operated

(2 trip detection logic)


  • Shift solenoid valve SL

  • Transmission wire

  • Harness and connector

  • TCM

P2770

TCM detects an open circuit in the solenoid valve SL circuit 2 times when solenoid valve SL is operated

(2 trip detection logic)


  • Shift solenoid valve SL

  • Transmission wire

  • Harness and connector

  • TCM

Fail-safe function:

If the TCM detects a malfunction, it turns shift solenoid valve SL off.

MONITOR DESCRIPTION

Based on the signals from the throttle position sensor, air flow meter and crankshaft position sensor, the TCM sends a signal to solenoid valve SL to regulate the hydraulic pressure and provide smooth torque converter clutch engagement. Shift solenoid valve SL responds to commands from the TCM and controls the lock-up relay valve to perform the torque-converter lock-up function. If the TCM detects an open or short circuit in the shift solenoid valve SL circuit, it will illuminate the MIL.

WIRING DIAGRAM

A01GHKOE05

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS AND TRANSMISSION WIRE (TRANSMISSION WIRE - TCM, TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL))


    1. A01GKZME05

      Disconnect the E6 TCM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E6-7 (SL) - Body ground Always 11 to 15 Ω

    NG
    OK
  2. REPLACE TCM


    1. Replace the TCM Click here.


    NEXT
  3. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)


    1. A01GJ47E07

      Disconnect the E50 transmission wire connector.

    2. Disconnect the E6 TCM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E50-7 (SL) - E6-7 (SL) Always Below 1 Ω
      E50-7 (SL) or E6-7 (SL) - Body ground Always 10 kΩ or higher

    NG
    OK
  4. INSPECT SHIFT SOLENOID VALVE SL


    1. A01GHWNE01

      Remove shift solenoid valve SL Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SL connector - Shift solenoid valve SL Body 20°C (68°F) 11 to 15 Ω
    3. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.

    NG
    OK