SHIFT LOCK SYSTEM INSPECTION


  1. INSPECT SHIFT LOCK SOLENOID


    1. A01GJP4E01

      Measure the resistance according to the value in the table below.

      Tech Tips

      Disconnect the solenoid connector.

      Standard resistance
      Tester Connection Condition Specified Condition
      3 (SLS-) - 4 (SLS+) 25°C (77°F) 104 to 126 Ω

      If the result is not as specified, replace the transmission floor shift assembly.

    2. A01GJP4E02

      Measure the resistance according to the values in the table below.

      Tech Tips

      Disconnect the solenoid connector.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 (P+) - 2 (P-) Push parking position switch 10 kΩ or higher
      1 (P+) - 2 (P-) Release parking position switch Below 1 Ω

      If the result is not as specified, replace the transmission floor shift assembly.