VALVE BODY ASSEMBLY INSPECTION


  1. INSPECT SHIFT SOLENOID VALVE SL1

    A01GNU1E12

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the shift solenoid valve SL1 - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SL1.

    2. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  2. INSPECT SHIFT SOLENOID VALVE SL2

    A01GNU1E13

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the shift solenoid valve SL2 - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SL2.

    2. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  3. INSPECT SHIFT SOLENOID VALVE SL3

    A01GNU1E14

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the shift solenoid valve SL3 - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SL3.

    2. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  4. INSPECT SHIFT SOLENOID VALVE SL4

    A01GNU1E15

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the shift solenoid valve SL4 - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SL4.

    2. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  5. INSPECT SHIFT SOLENOID VALVE SL5

    A01GNU1E16

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the shift solenoid valve SL5 - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SL5.

    2. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  6. INSPECT SHIFT SOLENOID VALVE SL

    A01GHWN

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SL connector - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SL.

    2. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  7. INSPECT SHIFT SOLENOID VALVE SLU

    A01GNU1E17

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the shift solenoid valve SLU - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SLU.

    2. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  8. INSPECT SHIFT SOLENOID VALVE SLT

    A01GNU1E18

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Terminal 1 of the shift solenoid valve SLT - Terminal 2 20°C (68°F) 5.0 to 5.6 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SLT.

    2. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.
  9. INSPECT SHIFT SOLENOID VALVE SR

    A01GL1Z

    1. Measure the resistance of the shift solenoid valve.

      Standard resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SR connector - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω

      If the resistance is not within the specified range, replace the shift solenoid valve SR.

    2. Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

      OK
      Valve moves and makes operating noise.