INTAKE AIR CONTROL VALVE ACTUATOR INSPECTION


  1. INSPECT INTAKE AIR CONTROL VALVE ACTUATOR

    A01GM5HE03
    Text in Illustration
    *a

    Component without harness connected

    (Intake Air Control Valve Actuator)

    *b Operation Angle 90°

    1. When battery voltage is applied between terminals 1 and 2 of the connector, check the operation of the actuator shaft.

      Standard
      Terminal Number (Battery Terminal) Specified Condition
      1 (battery terminal +) - 2 (battery terminal -) Actuator shaft rotates to left
      1 (battery terminal -) - 2 (battery terminal +) Actuator shaft rotates to right

      Note

      Apply battery voltage for 10 seconds or less each time the inspection is performed.