CANISTER INSPECTION


  1. INSPECT CANISTER

    A01GM89E01

    1. Visually check the canister for cracks or damage.

      If cracks or damage are found, replace the canister.

    2. A01GM89E02

      Blow 4.4 kPa (45 gf/cm2, 0.63 psi) of compressed air into port A and check that air flows without resistance from port B and port C. If the result is not as specified, replace the canister.

    3. Apply a vacuum of 1.96 kPa (20 gf/cm2, 0.28 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that the vacuum does not decrease when port B is released. If the result is not as specified, replace the canister.

  2. CLEAN FILTER IN CANISTER

    A01GKUTE01

    1. Clean the filter by blowing 4.4 kPa (45 gf/cm2, 0.63 psi) of compressed air into port A while holding port B closed.

      Tech Tips


      • Do not attempt to wash the canister.

      • No activated carbon should come out.