PURGE VALVE INSPECTION


  1. INSPECT VACUUM SWITCHING VALVE (PURGE VSV)


    1. A01GKWAE01

      Measure the resistance of the purge VSV.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω
      1 - Body ground Always 10 MΩ or higher
      2 - Body ground Always 10 MΩ or higher

      If the result is not as specified, replace the purge VSV.

    2. Check operation of the purge VSV.


      1. A01GLVSE01

        Check that air does not flow from port E to port F.

      2. A01GJD8E01

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the purge VSV.