CAMSHAFT TIMING CONTROL MOTOR ON-VEHICLE INSPECTION


  1. INSPECT FUNCTION OF CAMSHAFT TIMING CONTROL WITH EDU MOTOR ASSEMBLY


    1. Connect the intelligent tester to the DLC3.

    2. Turn the engine switch on (IG) and turn the tester on.

    3. Start the engine and warm it up.

    4. Engine is idling.

    5. Enter the following menus: Powertrain / Engine / Active Test / Control the VVT-iE Linear (Bank1) or Control the VVT-iE Linear (Bank2) / All Data / VVT-iE Aim Angle #1 and VVT Change Angle #1 or VVT-iE Aim Angle #2 and VVT Change Angle #2.

    6. Perform the Active Test operation with the engine speed at 1500 rpm.

      OK
      Active Test Movement Order Difference between "VVT-iE Aim Angle" and "VVT Change Angle"
      0 deg → 10 deg → 20 deg → 40 deg → 10 deg → 0 deg → 10 deg → END Within 4 DegFR

      If not within the standard, inspect the camshaft timing control with EDU motor assembly and camshaft timing gear assembly Click here.