VVT SENSOR INSTALLATION


  1. INSTALL VVT SENSOR


    1. A01GL9FE01

      Install the 4 VVT sensors with the 4 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    2. Connect the 4 VVT sensor connectors.

  2. INSTALL AIR CLEANER ASSEMBLY RH

    A01GM6U

    1. Install the air cleaner case with the 2 nuts and clip.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    2. Install the element to the air cleaner case.

    3. A01GIN9

      Install the air cleaner cap to the air cleaner hose assembly with the hose clamp.

      Torque:
      3.8 N*m  { 38 kgf*cm, 34 in.*lbf }

      Note

      Insert the protrusion of the air cleaner hose into the hole of the hose clamp.

      Tech Tips

      The hose clamp can be tightened within the range of 2.0 N*m (20 kgf*cm. 18 in.*lbf) to 5.5 N*m (56 kgf*cm. 49 in.*lbf).

    4. Install the air cleaner cap to the air cleaner case with the 2 clips.

    5. Connect the MAF meter connector.

  3. INSTALL AIR CLEANER ASSEMBLY LH

    A01GJKZ

    1. Install the air cleaner case with the 2 nuts and clip.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
    2. Install the element to the air cleaner case.

    3. A01GIOH

      Install the air cleaner cap to the air cleaner hose assembly with the hose clamp.

      Torque:
      3.8 N*m  { 38 kgf*cm, 34 in.*lbf }

      Note

      Insert the protrusion of the air cleaner hose into the hole of the hose clamp.

      Tech Tips

      The hose clamp can be tightened within the range of 2.0 N*m (20 kgf*cm. 18 in.*lbf) to 5.5 N*m (56 kgf*cm. 49 in.*lbf).

    4. Install the air cleaner cap to the air cleaner case with the 2 clips.

    5. Connect the MAF meter connector.

  4. INSTALL NO. 1 AIR CLEANER INLET

    A01GME8E01

    1. Align the holes with the connection areas labeled A, and attach the No. 1 air cleaner inlet.

    2. A01GM3N

      Install the No. 1 air cleaner inlet with the 2 bolts.

      Torque:
      5.0 N*m  { 51 kgf*cm, 44 in.*lbf }
  5. INSTALL AIR CLEANER INLET COVER SUB-ASSEMBLY

    A01GNHGE01

    1. Attach the 4 clips B.

      Note


      • Make sure the clips are attached securely.

      • Attaching the clips forcefully or hitting the top of the clips may damage them.

    2. Install the air cleaner inlet cover sub-assembly with the 5 clips labeled A.

  6. INSTALL V-BANK COVER SUB-ASSEMBLY

    A01GLQ5E01

    1. After sliding the cover from the vehicle front to the rear to attaching the 2 clips labeled A, attach the 4 clips labeled B and install the V-bank cover sub-assembly.

      Note


      • Make sure the clips are attached securely.

      • Attaching the clips forcefully or hitting the top of the clips may damage them.